Installation
Installation
  Note!
t  Covers of actioning cables are differently coloured
t  Check actioning cables before mounting and substitute tight moving cables or those that present imperfections
t  On turning the controls, all flaps should noticably reach max. position
   
–  Bend the end of the actioning cable -1- and press it against the control unit lever -2-, -arrow-.
–  Fit actioning cables of the footwell zone/deicer flap, of temperature flap and central flap with fixing clips.
Identification of the footwell zone/deicer flap actioning cable: Left hand drive vehicles: black Right hand drive vehicles: black
Identification of central flap actioning cable: Left hand drive vehicles: yellow Right hand drive vehicles: grey
Identification of temperature flap actioning cable: Left hand drive vehicles: blue Right hand drive vehicles: white
  N87-0318