Note t
| The pressure in the refrigerant circuit is governed by various factors of influence. As a general rule, however, the pressure should not exceed 20 bar at an ambient temperature of 20 to 25°C. Under extreme usage conditions (e.g. in hot countries with high ambient temperatures, “stop and go traffic” and high relative humidity), the high cooling output then required may also result in pressures of up to 31 bar. |
t
| At ambient temperatures below 25° C the pressure in the refrigerant circuit does not usually rise above 16 bar (radiator fan(s) -V7- run(s) and cool(s) condenser). |
t
| Duty cycle (reading measured value block, display group “001”, display zone “3”) is used by operating and display unit (Climatronic control unit -J255-) to calculate pressure in refrigerant circuit. |
t
| With a test ration less than 12.5 % (equivalent to approx. 1.8 bar absolute pressure) and more than 87.5 % (equivalent to about 32 bar absolute pressure), the operating and display units of the Climatronic control unit -J255- does not switch on the compressor (the air conditioning system compressor regulating valve -N280- is not actuated). The compressor is only reactivated once the signal ratio exceeds 12.5 % (corresponding to an absolute pressure of 1.8 bar) or drops below 48 % (corresponding to an absolute pressure of 16 bar). |
t
| To prevent abrupt compressor shutoff on account of excessive pressure in refrigerant circuit or excessive coolant temperature, compressor output is reduced by operating and display unit, Climatronic control unit -J255-: |
t
| - As soon as the pressure in the refrigerant circuit exceeds 30 bar (absolute) (full compressor output is not released again until the pressure has dropped below 27 bar). |
t
| - A soon as the coolant temperature exceeds 115 °C (deactivated completely from 118 °C). |
t
| If the pressure in the refrigerant circuit had been in excess of 32 bar (duty cycle greater than 87.5 %), the operating and display unit, Climatronic control unit -J255- does not re-activate the compressor until the pressure has dropped below 29 bar (duty cycle less than 84 %). |
t
| For further notes on pressure in refrigerant circuit, refer to “Reading measured value block”, display group “001”. |
|
|
|