Pump-injector set: removing and installing|Remove > < Pump-injector unit with new solenoid valve nut
Continue for both models of pump-injector unit
Continue for both models of pump-injector unit
–  If necessary, re-adjust the pump-injector and tighten the fixing screw as follows: 12 Nm and 270° (3/4 turn) (the tightening process can be carried out in various stages)
–  Fit the rocker arm shaft and tighten the fixing screws as follows.
–  Uniformally tighten the internal, then the external screws, by hand. Next, and in the same order, tighten to 20 Nm and ¼ turn (90°).
   