| Remove the deaeration tube -2- of the activated carbon tank -1- from the butterfly valve control unit -3-. |
–
| Attach the tube -2- to the manual vacuum pump -SAT 1390-. |
–
| Separate the ventilation tube -5- which goes from the fuel tank to the activated carbon tank, and fit it to the pressure fall tester -V.A.G 1368-“connection A”; to do so, use adapter -SAT 1368/1-. |
–
| Fit the pressure fall tester -V.A.G 1368-“connection B” to the ventilation tube -4- which goes to the activated carbon tank. To do so, use adapter -SAT 1368/1-. |
–
| Set the pressure fall tester in position “B”. |
–
| Operate the manual pump -SAT 1390- several times. Suction should not be created. |
–
| Check the aeration connection -6- of the activated carbon tank -1- for dirt; if necessary, clean. |
If suction is not created: |
–
| Unscrew the plug from the fuel filler hole. |
|
|
|