Valve -1- for variable distribution N205 : checking > < Variable valve timing: checking
Solenoid valve: checking
Solenoid valve: checking
–  Switch off ignition.
   
–  Extract the connector -arrows- of the variable distribution system valve -N205-.
  A15-0571
–  Measure solenoid valve resistance with measuring tool set -VAG 1594C-.
t  Specification: 10 to 18 Ω.
If specification is not attained:
–  Renew solenoid valve.
If specification is not attained:
–  Check supply voltage.
  A28-0019