| Connect hand pump -SAT 1390- to vacuum hose -1-. |
Note Do not use compressed air during the following check! |
–
| Detach pressure hose from secondary air pump motor. |
Note To do this, press in ribbed parts of coupling |
–
| Lightly blow into pressure hose -arrow-. |
Combi-valve must be closed. |
–
| Operate hand vacuum pump. |
If the combi-valve does not open: |
–
| Renew combination valve . |
|
|
|