t
| Vacuum pump -VAS 6213-, see equivalent → Anchor |
–
| Check all vacuum lines in the complete vacuum system for: |
t
| Kinked or crushed lines |
t
| Lines porous or leaking |
–
| Check vacuum line to solenoid valve and from solenoid valve to corresponding component. |
–
| When saving an event, the vacuum line must be checked for the respective component as well as to each of the other components. |
–
| If it is not possible to build up pressure with the hand vacuum pump -VAS 6213- or if the pressure drops again immediately, check the hand vacuum pump and connecting hoses for leaks. |
|
|
|