WARNING Hot steam may be emitted on opening the expansion tank. The sealing cap must be be covered with a cloth and opened carefully. |
|
–
| Open the cap of the coolant expansion tank. |
–
| Place cooling system tester -SAT 1274- into the expansion tank with the adapter -VAG 1274/8-. |
–
| Using the hand pump on the tester, build up a pressure of approx. 1 bar. |
If the pressure now drops: |
–
| Look for the point of leakage in the installation and eliminate the fault. |
Check pressure relief valve in filler cap |
–
| Place cooling system tester -SAT 1274- in filler cap with adapter -VAG 1274/9-. |
–
| Operate hand vacuum pump. The pressure release valve must open at an excess pressure of 1.4 … 1.6 bar. |
|
|
|