| Separate the flexible depression tube -5- from the depression tubes -4- and connect the manual pressure/depression pump -SAT 1390-. |
–
| Separate the flexible depression tube -1- from the exhaust gas recirculation valve. |
–
| Remove the double connector -3- from the two-way exhaust gas recirculation valve -N161--2-. |
–
| Start the engine and let it run at idle. |
–
| Operate the pump. A depression should occur. |
–
| Connect the double connector -3- to the two-way exhaust gas recirculation valve -2-. The depression in the pump should immediately disappear. |
|
|
|