| Disconnect vacuum hose from vacuum unit and connect the hand vacuum pump -VAS 6213- in its place. |
–
| Operate hand vacuum pump to create a vacuum. |
l
| The linkage of the changeover for the exhaust gas recirculation cooler must move -arrows-. |
If linkage does not move or only moves in jerks: |
t
| The vacuum unit is defective. |
t
| The change-over flap for exhaust gas recirculation is sticking. |
|
|
|