| Connect manual vacuum pump -VAS 6213- to solenoid valve 1 for activated charcoal filter -N80- . |
–
| Connect contacts of activated charcoal filter solenoid valve 1 -N80--1- to battery using test leads. This will open activated charcoal filter solenoid valve 1 -N80-. |
Then immediately operate hand vacuum pump -VAS 6213- several times. |
l
| A vacuum must build up. |
–
| Reconnect battery (interrupt power supply). |
If a vacuum does not build up: |
–
| Replace double non-return valve -1-. |
The double non-return valve, the solenoid valve 1 for the activated charcoal filter -N80- and the plastic hoses are component and cannot be replaced separately. |
|
|
|