| Remove the pressure hose -arrow- from the Secondary air pump motor -V101- . |
Note To release the tubes press hose connections together. |
–
| Blow lightly into the pressure hose to the combination valve. Combi-valve must be closed. |
–
| Blow strongly into the pressure hose to the combination valve. Combination valve must open. |
If the combi valve does not open or is always open: |
–
| Renew combination valve . |
|
|
|