Read the measurement value blocks
Read the measurement value blocks
Special tools and workshop equipment required
   
t  Fault reader -V.A.G 1551-
  W00-0459
t  -V.A.G 1551/3B- cable
  Note!
t  The equipment -V.A.G 1552- may be used instead of the -V.A.G 1551-, however in this case the results cannot be printed.
t  Presently, in the measurement block, only the following values may be read in the indication group 01:
  W00-1038
 Indication fields
 1234
Indication group 01
Displayxxxx/minxx,x msxxx,x %xx,x mm3
IndicationEngine speedSupply timeValve connection time for the commencement of the injection cycleSupply intensity

Test conditions
l  Refrigerant liquid temperature, 80 °C minimum
l  All consumer electrics should be connected, for example: the lights and the heated rear window
l  For vehicles fitted with air conditioning, the air conditioning should be disconnected
l  There should be no recorded faults already in the memory → Chapter.
Verification process
–  Connect the equipment -V.A.G 1551- (-V.A.G 1552-) and, using the corresponding “address code” 41, select the diesel pump electronic control unit. While doing this, the engine must be running idle → Chapter.
   
Display indication:
–  Press the keys 0 and 8 for the function “Read measurement block values”, confirm using the key Q.
 
Rapid data transmission             HELP
Select the function XX                  
Display indication:
–  Press the keys 0 and 1 for “Indication group 01” and confirm using the key Q.
 
Read measurement block values           
Input the indication group number XX    
Display indication:
–  Read the idle engine speed in the indication field 1.
   Theoretical value: 900 ± 30/min
–  Do not observe the supply time indicated in the indication field 2 (it is not the theoretical value).
–  Read the valve connection time for the commencement of the injection cycle, indicated in the field 3.Theoretical value: Control unit with green point 40...48%. Control unit without green point: 27...44%
–  Read the supply rate, indicated in the field 4.
   Theoretical value: 3...12 mm3
–  If the theoretical values do not appear in the fields 3 and 4, replace the injection timing sender -G175- ersetzen → Item.
 
Read measurement block values 1       ->
930/min          -         37%         5

Self diagnosis > < Fault memory: consulting