seat Workshop Repair Guides

SEAT Workshop Service and Repair Manuals

Fuel supply, gas operation > < Removing and installing thermostat
4-cyl. injection engine (2 valve without intermediate shaft), Mechanics
Removing and installing parts of cooling system
Checking coolant circulation pump (V50)

Special tools, workshop equipment, testers, measuring instruments and auxiliary items required

 
W00-0513
  • ◆ → V.A.G 1527 B Diode test lamp

 
W00-0477
  • ◆ → V.A.G 1594 A Auxiliary test set
  • ◆ Current flow diagram
 
N01-0485

Check conditions

  • ● → Fuse No. 16 OK.

Functional check

 
N19-0314
  • ‒ Pull 2-pin connector -arrow- off coolant circulation pump (V50).
 
N19-0175
  • ‒ → Connect contacts of coolant circulation pump (V50) to battery using adapter cables from V.A.G 1594 A.
        Coolant circulation pump must run.

If the coolant circulation pump does not run:

  • ‒ Replace coolant circulation pump (V50).

If the coolant circulation pump (V50) runs:

  • ‒ Switch ignition off and on again.

Checking activation

 
M26-0009
  • ‒ → Connect diode test lamp V.A.G 1527 B to disconnected connector for coolant circulation pump (V50) with aux. cables from V.A.G 1594 A
        LED must light up.

Note:

This check must be performed within 3 minutes of switching ignition off.

LED does not light up:

  • ‒ Locate and rectify open circuit using current flow diagram:

=> Current flow diagrams, Electrical fault finding and Fitting locations

Fuel supply, gas operation > < Removing and installing thermostat