seat Workshop Repair Guides

SEAT Workshop Service and Repair Manuals

Removing and installing coolant pump > < Checking radiator fan
5-cyl. injection engine, (4-valve), Mechanics
Removing and installing parts of cooling system
Checking continued coolant circulation pump
 
W00-0513

Special tools, workshop equipment, testers, measuring instruments and auxiliary items required

  • ◆ V.A.G 1527 B Diode test lamp

 
W00-0477
  • ◆ V.A.G 1594 A Auxiliary test set
  • ◆ Current flow diagram

Check conditions

 
N01-0485
  • ● → All fuses must be OK.

Test sequence

 
N19-0314
  • ‒ → Pull 2-pin connector off continued coolant circulation pump (V51) -arrow- .

Functional check

 
N19-0175
  • ‒ → Connect contacts of continued coolant circulation pump (V51) to battery using auxiliary cables from V.A.G 1594.
        Continued coolant circulation pump must run.

If the continued coolant circulation pump does not run:

  • ‒ Replace continued coolant circulation pump (V51).

If the continued coolant circulation pump (V51) runs:

Checking activation

  • ‒ Switch ignition off and on again.
 
M26-0009
  • ‒ → Connect diode test lamp V.A.G 1527 B to disconnected connector for continued coolant circulation pump (V51) with auxiliary cable from V.A.G 1594 A
        LED must light up.

Note:

This check must be performed within 3 minutes of switching ignition off.

If the LED does not light up:

  • ‒ Locate and rectify open circuit using current flow diagram:

=> Current flow diagrams, Electrical fault finding and Fitting locations

Removing and installing coolant pump > < Checking radiator fan