Leon Mk2
Note: The vehicle system tester V.A.G 1552 can be used instead of the fault reader V.A.G 1551, however a print-out is not possible. |
Test conditions |
=> Repair group 01; Fault memory; Interrogating and erasing fault memory of engine control unit
Checking activation
=> Repair group 01; Final control diagnosis; Performing final control diagnosis If activation is OK:
Test sequence
|
→ Indicated on display: |
|
||
|
→ Indicated on display: |
|
||
|
→ Indicated on display: |
|
||
|
→ Indicated on display: (1...4 = Display zones) |
|
||||||||||||||||||||||||||||||
If the specifications are not obtained:
=> Repair group 01; Fault memory; Interrogating and erasing fault memory of engine control unit
=> Repair group 01; Readiness code; Reading out readiness code
=> Repair group 01; Readiness code; Generating readiness code If no fault is stored in fault memory:
If the specification is attained:
|
→ Indicated on display: (1...4 = Display zones) |
|
||||||||||||||||||||||||||||||
If the specifications are not obtained:
=> Repair group 01; Fault memory; Interrogating and erasing fault memory of engine control unit
=> Repair group 01; Readiness code; Reading out readiness code
=> Repair group 01; Readiness code; Generating readiness code If no fault is stored in fault memory:
If the specification is attained:
Checking camshaft adjustment
|
→ Indicated on display: (1...4 = Display zones) |
|
||||||||||||||||||||||||||||||
Note on display zones 1 and 2: The display values rise to about 52.0 °and then decline again to specification. Note on display zone 4: The specification "xxxxx100" in display zone 4 appears only after about 40 seconds. If the specifications are not obtained:
=> Repair group 01; Fault memory; Interrogating and erasing fault memory of engine control unit
=> Repair group 01; Readiness code; Reading out readiness code
=> Repair group 01; Readiness code; Generating readiness code If no fault is stored in fault memory:
=> Repair group 28; Servicing ignition; Checking Hall senders
If no wiring fault is detected:
If the specification is attained:
|
→ Indicated on display: (1...4 = Display zones) |
|
||||||||||||||||||||||||||||||
Note on display zones 1 and 2: The displayed values rise to about 22.0 °CA and then decline again to specification. Note on display zone 4: The specification "xxxxx100" in display zone 4 appears only after about 40 seconds. If the specifications are not obtained:
=> Repair group 01; Fault memory; Interrogating and erasing fault memory of engine control unit
=> Repair group 01; Readiness code; Reading out readiness code
=> Repair group 01; Readiness code; Generating readiness code If no fault is stored in fault memory:
=> Repair group 28; Servicing ignition; Checking Hall senders
If no wiring fault is detected:
If the specification is attained:
|