Release lever -D- and press the tabs -E- together.
–
Detach the connector -C- of the defroster flap control motor -V107-.
–
Detach control motor -B-.
Installation
Note
The lever -E- on the servomotor and the connecting rod -D- are colour coded. These are blue on the defroster flap control motor -V107-.
Re-install all parts removed in reverse order; note the following:
–
Route wiring harness so that it cannot come into contact with moving components (e.g. control motor lever).
Note
t
All cable ties and other electric wiring harness fasteners released or severed when removing the air conditioner unit are to be re-attached in the same position on fitting.
t
Use the respective tightening torques.
–
Consult the fault memory of the Climatronic control unit -J255- and erase the faults that appear → Vehicle diagnostic tester.
–
Carry out the basic adjustment and diagnostic of the air conditioning actuators the consult the fault memory once again → Vehicle diagnostic tester.