Servomotor for the air retention flap -V71- with Potentiometer - servomotor for air retention flap -G113-: removing and fitting |
Note t
| Operation of control motor can be checked in the following manner, for example: Connect the two pins “5” and “6” in the servomotor plug to a 12V DC voltage supply, the servomotor will move to the maximum position in only one direction, exchanging the positive and negative poles modifies the direction of turn. Use adapter cable for this purpose → Chapter. |
t
| The Servomotor for the air retention flap -V71- can only be removed when in the position “full fresh air position”; it can only be refitted in this position. If the servomotor is stopped in any other position and it may not be moved into the position of “maximum fresh air ”, it will be difficult to remove and dismantle. |
t
| Different versions of the servomotor in vehicles fitted with heating or air conditioning (with end of run switches and potentiometers) → Parts catalogue. |
|
|
|