| Check the fastener -H- (not fitted to all junctions) and the sleeve -I- for correct seating and damage. |
–
| Tighten bolts -A- and -D- to 25 Nm. |
Note t
| Use is not to be made of O-ring seals from caps of replacement compressor connections. |
t
| Lightly oil the O-rings with oil from the refrigerant circuit just before fitting → Chapter. |
t
| Ensure that the O-ring seals seat correctly into the groove -G- in the tubes of the refrigerant agent. |
t
| Following attachment of the refrigerant pipes to the compressor (and compressor itself), check correct layout, They must be inserted in holders provided and not make contact with other components. |
|
|
|