Leon Mk2
Disassembling and assembling the air conditioning unit |
Installation overview |
Note
Union elements of the air conditioning unit in → Fig. |
1 - | Wiring harness for the air conditioning unit |
q | To remove it, carefully cut the cable tie. |
q | When assembling, use a new cable tie in the same place. |
2 - | Upper section of the evaporator housing |
q | Joint between upper and lower sections with screws and with staples on → Fig. |
3 - | Support |
q | Threaded union in the module bracket and in the heating unit; 12 Nm |
q | Torque for the air conditioning unit: 5 Nm |
4 - | Preliminary resistance for the fresh air fan -N24- |
q | Removing and fitting → Chapter |
5 - | Foam rubber gasket |
q | Replace if it has defects. |
q | Self-adhesive |
q | Stuck to the evaporator housing |
q | Before assembly, remove all traces of adhesive with acetone. |
6 - | Expansion valve |
q | Assembly overview → Chapter |
7 - | Housing air inlet |
q | With fresh air and air recirculation flap |
q | Fixed on the upper and lower sections of the housing with staples in → Fig. |
8 - | Gasket |
q | Replace if it has defects. |
q | Self-adhesive |
q | Before assembly, remove all traces of adhesive with acetone. |
9 - | Dust and pollen filter |
q | Also as a combined filter with the odour filter |
10 - | Regulating motor for the fresh air and circulation air intake flap-V154- |
q | Removing and fitting → Chapter |
q | Fit it into the support |
11 - | Support |
q | Regulating motor for the fresh air and circulation air flap -V154- |
12 - | Fresh-air fan -V2- |
q | Removing and fitting → Chapter |
13 - | Support for the fresh air fan -V2- |
q | Remove the support for the fresh air fan → Chapter |
14 - | Lower section of the evaporator housing |
q | Join lower-upper sections with bolts and with staples → Fig. |
15 - | Filter cover |
16 - | Distributor housing, lower section |
17 - | Heating element for the secondary heating (PTC) -Z35- |
q | Removing and fitting → Chapter |
18 - | Heat exchanger |
q | Removing and fitting → Chapter |
19 - | Air distribution flap control unit |
q | Removing and fitting → Chapter |
20 - | Gasket for evaporator |
q | Note the installation position: The water outlets must face downwards. |
21 - | Evaporator |
q | Removing and fitting → Chapter |
22 - | Distributor housing, upper section |
q | In the upper and lower sections of the evaporator housing |
23 - | Left support |
q | Threaded union in the module bracket, air conditioning unit and central console support; 12 Nm |
q | Torque for the air conditioning unit: 5 Nm |
q | Torque for central console support: 12 Nm |
24 - | Support |
q | for the regulating motor for temperature flap -V68-. |
25 - | Regulating motor for temperature flap -V68- |
q | Removing and fitting → Chapter |