| Check wiring for open circuit between test box and connector according to current flow diagram. Contact 5+ socket 2 Contact 5+ socket 28 Contact 6+ socket 59 Contact 6+ socket 66 Contact 6+ socket 80 Wire resistance: max. 1.5 Ω |
–
| Additionally check wires for short to one another, to vehicle earth and to battery positive. Specification: ∞Ω |
If no wiring fault is detected: |
|
|
|