Leon Mk2
Thermostat housing - exploded view of components |
1 - | O ring |
q | Replace |
2 - | Thermostat housing |
q | removing and fitting → Chapter |
3 - | O ring |
q | Replace |
4 - | Lower coolant pipe |
q | removing and fitting → Chapter |
5 - | 10 Nm |
6 - | 15 Nm |
7 - | O ring |
q | Replace |
8 - | Heating element connection |
q | 14 … 16 Ω at 25 °C |
q | Cannot be renewed as a separate unit |
9 - | Connector |
10 - | With Cooling system thermostat managed on the basis of a map of characteristics -F265- |
q | With connection nozzle |
q | removing and fitting → Chapter |
q | Checking → Chapter |
q | Starts to open at approx. 105 °C |
q | Minimum opening distance 7 mm |