| Unscrew the bolts -arrows- and remove the upper air filter housing. |
Note –
| Lift the upper element of the air filter housing and remove the air filter cartridge. |
For the air mass gauge -G70- to work properly, respect the instructions and work procedures which are described below. |
Note t
| If the air filter element is very dirty or wet, dirt or water could reach the air mass meter -G70- and affect the air mass value. This would lead to loss of power, since a smaller injection quantity is calculated. |
t
| Always use genuine part for air filter element. |
t
| Hose connections and hoses for charge air system must be free of oil and grease before assembly. Do not use any lubricants containing silicone when assembling. |
t
| The air filter housing elements must be clean. |
t
| Upon blowing the air filter housing with pressurised air take note of the following: To prevent malfunctions, cover all critical parts of the engine air intake tract such as air mass meter, intake pipes, etc. with a clean cloth. |
t
| Observe environmental regulations for disposal. |
|
|
|