seat Workshop Repair Guides

SEAT Workshop Service and Repair Manuals

Injection pump: removal and refitting > < Motor for plate in inlet manifold: removal and refitting
Injection pump: repair
   
Injection pump: repair
t  Observe the rules for cleaning → Chapter
t  Removal and refitting the injection pump → Chapter
t  Check and dynamically adjust the start of the injection → Chapter
t  Always replace seals and o rings
1 - 25 Nm
q   Replace
2 - Injection pump pinion
q   Removal → Chapter, Injection pump: removal and refitting
3 - Fixing nut
q   For hub
q   Not to be released in any case. Otherwise, the basic adjustment of the injection pump would go out of phase; adjustment is not possible with the workshop equipment
4 - Connection sleeve, 25 Nm
q   For supply pipe
q   From the fuel filter
5 - Injection pump
q   With dosing servomechanism
q   With doser -N146-
q   With stroke transmitter of the regulator slide -G149-
q   With fuel temperature transmitter -G81-
6 - Fuel cut valve -N109-, 40 Nm
q   Check → Chapter, Actuator diagnosis
7 - Connection sleeve
q   For return pipe
8 - Return pipe
q   To the regulator valve/fuel filter
9 - 25 Nm
10 - Injection pipe
q   Tighten to 25 Nm
q   Remove with -U-40072-
q   Remove the complete set of pipes
q   Do not alter the bends
11 - Connection sleeve, 45 Nm
With pressure valve
12 - 25 Nm
13 - Injector
q   For cylinder 3 with needle stroke transmitter -G80-
q   Check the needle stroke transmitter → Chapter
q   Removal and refitting → Chapter
q   Repair → Chapter
14 - 20 Nm
15 - Support flange
16 - Support
17 - Heatproof seal
q   Replace
18 - 10 Nm
19 - Injection start valve -N108-
q   Check → Chapter, Actuator diagnosis
20 - Filter
21 - O ring
q   Replace
22 - 25 Nm
23 - Lid for the injection regulator corrector
q   Should the seal be incorrect, replace the o ring → Anchor
24 - Bushing
q   With nut
25 - Console
q   Removal and refitting → Rep. Gr.13
26 - 25 Nm

   

Injection pump: removal and refitting > < Motor for plate in inlet manifold: removal and refitting