| Pull the 4-pin connector off coolant temperature sender -G62- with coolant temperature gauge sender -G2--arrow-. |
If the display jumps to -40 °C: |
–
| Press keys 0 and 6 for the “End output” function and confirm input with the Q key. |
–
| Replace coolant temperature sender -G62- with coolant temperature gauge sender -G2- → Item. |
If the display remains at 120 °C: |
–
| Press keys 0 and 6 for the “End output” function and confirm input with the Q key. |
|
|
|