seat Workshop Repair Guides

SEAT Workshop Service and Repair Manuals

Match balancing > < Radial and axial wheel eccentricity: Check
Radial and axial rim eccentricity: Check
Radial and axial rim eccentricity: Check
Consult the equivalence table for tools and equipment according to applicability between Seat / VW / Audi / Skoda → Chapter.
Special tools and workshop equipment required
t  Micrometer sphere -V.A.G 1435-
–  Fasten the whole wheel on the balancer.
–  Apply a prior stress of 2 mm to the micrometer dial -V.A.G 1435-.
–  Turn the wheel slowly.
   
–  Note the minimum and maximum values recorded.
S  - Axial run-out
H  - Radial run-out
–  Compare the measured values with the theoretical values in the table → Anchor.
  Note
Ignore the one-off peak measurements on the micrometer caused by the elevation or depression of the material.
  N44-0231
Theoretical values of radial and axial run-out
RimRadial run-out (mm)Axial run-out (mm)
Passenger vehiclesSteel wheel rims0,50,5
 Light alloy wheel rims0,50,8
Mono volumeSteel wheel rims0,50,8
 Light alloy wheel rims0,50,5

  Note
If the measured value exceeds the theoretical value, the noise when driving will increase to unacceptable levels.
   

Match balancing > < Radial and axial wheel eccentricity: Check