Workshop Manuals Factory service & repair SEAT
01 Technical data02 Engine assy, cylinder block, crankcase03 Enginecrankshaft group, pistons04 Engine cylinder head, valve gear05 Engine lubrication06 Engine cooling07 Fuel supply, gas operation08 Exhaust turbocharger, G-charger09 Fuel preparation system Diesel injection10 Mixture preparation system, electronic inj., Gas11 Exhaust system12 Starter-current supply-CC13 Ignition system, glow plug system14 Clutch, control15 Gearbox mechanics, operation, construction, diff.16 Gearbox, mechanics, gears, shafts, internal operation17 Final drive, differential, differential lock18 Front suspension, drive shafts19 Rear suspension, drive shaft20 Self-levelling air spring system21 Wheels, tyres. axle align22 ABS, ADR, TCS, EDL, ESP23 Brake, brake mechanics24 Brakes, hydraulics, regulator, servo25 Steering26 Body front27 Body centre, roof, frame28 Body, rear29 Bonnet, flaps, cab, central locking30 Front door, central locking31 Rear door, sliding door, wing doors, central locking32 Sliding roof33 Bumper34 Glazing/window mechanism35 Exterior equipment36 Interior equipment37 Passenger protection38 Trim, noise insulation39 Seat frames40 Seat padding, covers41 Heating42 Air conditioner43 Instruments, GCI44 Infotainment45 Windscreen wipe/wash system46 Lights, lamps, switches outside47 Lights, lamps, switches inside, anti-theft system48 Wiring
SEAT León (5F, 2012-2020)01 · Technical data
01 · General

Air conditioning

Make
SEAT
Model
Leon León
Year
5F, 2012–2020
Section
Security standards › Air conditioning
Technical dataAir conditioning

Air conditioning

Security standards · León from 2013 · Edition 01.2014

Do not weld, braze or soft-solder any parts of the charged air conditioning system. This also applies to welding and soldering work on the vehicle if there is a danger of air conditioner components becoming hot. When performing paintwork repairs, the vehicle must not be heated to more than 80 ℃ in the drying oven or the preliminary heating zone, because heat causes a strong pressure increase in the facility, which can burst the air conditioner system.

Note

  • The refrigerant must also be extracted from the circuit when arc-welding anywhere near the refrigerant hoses. Arc-welding emits invisible ultraviolet rays which can penetrate the refrigerant hoses and decompose the refrigerant.

Solution:

Refrigerant circuit extraction, Air-conditioning with refrigerant R134a Rep. gr. 00. The system is only to be drained if this is necessary for safety measures.

If vehicle repairs necessitate extraction of the refrigerant, take care to avoid contact with liquid refrigerant or refrigerant vapours.

Wear rubber gloves to protect the hands and goggles to protect the eyes! If the refrigerant comes into contact with unprotected parts of the body it will cause frostbite.

Warning

We recommend that a bottle with liquid is kept at hand in case your eyes need to be rinsed. If refrigerant comes into contact with your eyes, rinse thoroughly with plenty of water 15 minutes long.

Then apply eye drops and consult a doctor immediately even if the eyes are not causing any pain. The doctor must be informed that the frostbite was caused by refrigerant R134a.

If the refrigerant comes into contact with other parts of the body despite compliance with safety measures, the part of the body concerned must be rinsed immediately with cold water for at least 15 minutes. Air conditioner with refrigerant R134a Rep. gr. 00

Although the refrigerant does not pose a fire risk, smoking is prohibited in rooms where there are refrigerant vapours. The high temperature of a burning cigarette causes chemical decomposition of the refrigerant gas. Inhaling the toxic products of decomposition can cause a dry cough and nausea.

Parts & tools for this job For 2012 SEAT Leon