General description - start/stop system
- Make
- SEAT
- Model
- Mii
- Year
- 2011–2021
- Section
- Electrical system › General description - start/stop system
General description - start/stop system
The start/stop system is used for reducing fuel consumption by automatically switching off the engine when the vehicle is stationary and automatically starting it when the driver wants the vehicle to move on. The start/stop mode is automatically activated when, after moving on, the vehicle is driven for about four seconds at a minimal speed of 3 km/h.
Following control units are involved in the start/stop system:
- Data bus diagnostic interface J533 in the onboard power supply control unit J519
- Engine control unit J623
- ABS control unit J104
When recharging the battery or jump starting vehicles with a start/stop system, the following must be observed: using the charging cable, first connect the positive terminal and then connect to the body earth. This ensures that the battery sensor is not shunted. The direct charging of the battery on the negative terminal clamp means that the battery sensor is shunted and the battery data are not registered by the sensor while charging. Then, the values concerning the battery state and saved in the data bus diagnostic interface would not correspond to the values of the charged battery.
Because of its higher deep-cycle resistance, only a special starter battery is used in vehicles with a start/stop system.
When renewing the starter battery, note correct part designation in ETKA (electronic parts catalogue). Starter batteries for use in vehicles with a start/stop system are marked with “AGM” (Absorbent Glass Mat) or “EFB” (Enhanced Flooded Battery).
The start/stop system as a function is integrated in the engine control unit J623 software.
The engine control unit J623 features self-diagnosis to facilitate fault finding.
To localise faults, refer to chapter entitled “Vehicle diagnosis, testing and information system” and use “Guided fault finding” function.
The voltage stabiliser J532 is secured on the floor covering under the left front seat. It has the task of stabilizing to 12 volts the high voltage fluctuations generated in the onboard supply by the start/stop operation.
If the voltage stabiliser is defective, devices like radio, radio navigation or telephone will perform a reset if their own voltage supply is not sufficient when the starter is operated. If, in start/stop mode, the mentioned electrical consumers are identified as causing a reset for each motor start, this indicates a defective voltage stabiliser. A direct entry concerning a malfunction of the voltage regulator, e.g. in the event memory of the diagnostic interface or the onboard supply control unit, does not occur at present. If radio, radio/navigation and telephone units have failed together, first check fuse of voltage stabiliser.
Parts & tools for this job For 2011 SEAT Mii
- TOOLDigital multimeterSearch: automotive digital multimeter
- PARTAssorted fuse kitSearch: car fuse assortment kit
- TOOLWire crimper and connector kitSearch: wire crimper connector kit