01 Technical data02 Self diagnosis, V.A.G Inspection Service03 Engine assy, cylinder block, crankcase04 Enginecrankshaft group, pistons05 Engine cylinder head, valve gear06 Engine lubrication07 Engine cooling08 Fuel supply, gas operation09 Exhaust turbocharger, G-charger10 Fuel preparation system Diesel injection11 Mixture preparation system, electronic inj., Gas12 Exhaust system13 Starter-current supply-CC14 Ignition system, glow plug system15 Clutch, control16 Torque converter17 Gearbox mechanics, operation, construction, diff.18 Gearbox, mechanics, gears, shafts, internal operation19 Automatic gearbox, control, assembly, housing20 Automatic gearbox, gears, control21 Final drive, differential, differential lock22 Front suspension, drive shafts23 Rear suspension, drive shaft24 Wheels, tyres. axle align25 ABS, ADR, TCS, EDL, ESP26 Brake, brake mechanics27 Brakes, hydraulics, regulator, servo28 Steering29 Body front30 Body centre, roof, frame31 Bonnet, flaps, cab, central locking32 Front door, central locking33 Rear door, sliding door, wing doors, central locking34 Sliding roof35 Bumper36 Glazing/window mechanism37 Exterior equipment38 Interior equipment39 Passenger protection40 Trim, noise insulation41 Seat frames42 Seat padding, covers43 Heating44 Air conditioner45 Infotainment46 Windscreen wipe/wash system47 Lights, lamps, switches outside48 Lights, lamps, switches inside, anti-theft system49 Wiring
SEAT Toledo (5P, 2004-2009)44 · Air conditioner
44 · Heating & A/C

Safety measures when handling refrigerant

Make
SEAT
Model
Toledo
Year
5P, 2004–2009
Section
Heating, air conditioning › Safety measures when handling refrigerant
Air conditionerSafety measures when handling refrigerant

Safety measures when handling refrigerant

Heating, ventilation, air conditioning system · Heating, air conditioning · Instructions for repair work on vehicles with air conditioning and how to work with the refrigerant · Toledo from 2005, Altea · Edition 10.2011

The following safety measures are to be observed in Germany for this refrigerant (additional regulations may apply in other countries).

The refrigerant circuit must be discharged first should repair work require the refrigerant circuit to be opened Chapter “Safety precautions”. All contact with liquid refrigerant or refrigerant vapours should be avoided. Should refrigerant nevertheless escape, avoid inhaling the resultant refrigerant/air mixture.

Therefore, switch on extraction systems and wear rubber gloves and protect eyes with safety goggles.

Reasons:

Intensive exposure to refrigerant would cause frostbite on unprotected parts of the body.

Warning

It is recommended that you always have an eye-bath ready for use in case it is needed.

Should liquid refrigerant come into contact with the eyes, rinse them thoroughly with water for about 15 minutes.

Then apply eye drops and consult a doctor immediately, even if you do not experience any pain in the eyes.

Always inform the doctor of the type of refrigerant involved.

Should refrigerant come into contact with other parts of the body despite compliance with all the pertinent safety measures, these are similarly to be rinsed thoroughly with cold water without delay for at least 15 minutes.

Although refrigerants do not represent a fire hazard, smoking, welding, soldering and brazing are not permitted in areas exposed to refrigerant.

Reasons:

The high temperature of a naked flame or hot objects causes decomposition of refrigerant gas. Inhalation of the toxic decomposition products causes dry coughing and nausea.