Removing and installing temperature flap actuator
- Make
- SEAT
- Model
- Toledo
- Year
- KG, 2012–2019
- Section
- Heating, air conditioning › Removing and installing temperature flap actuator
‹ Prev Position of the components of the heaterNext › Removing and installing fresh air and air recirculation flap control motor V154, vehicles 05.2008
HeatingRemoving and installing temperature flap actuator
Removing and installing temperature flap actuator
Unclip cable on temperature flap actuator (2).Chapter “Removing and installing Bowden cable for temperature adjustment, vehicles ¶% 05.2008”

Release the block (1) and push the air distribution flap control mechanism in the direction of the (arrow) as far as it will go.
Pull off temperature flap actuator.
Installation is carried out in reverse order.
Note
- position to position.
‹ Prev Position of the components of the heaterNext › Removing and installing fresh air and air recirculation flap control motor V154, vehicles 05.2008