Fabia Mk1
Overview of the control units for convenience system with CAN databus cable |
Control unit part No. → Note | Program number | Control unit function | |
Central control unit for convenience system | Door control unit | ||
6Q0959433A 01 6Q0959433H 35 | - | 0002 | Control unit without power-window lifter, without radio control and without alarm function LHD |
6Q0959433C 02 6Q0959433E 3A | - | 0002 | Control unit without power-window lifter, with radio control without alarm function LHD |
6Q0959433C OK | - | 0002 | Control unit without power-window lifter, with radio control and alarm function (with interior monitoring) without alarm system with independent power supply LHD |
6Q0959433C 03 6Q0959433E 2P | - | 0002 | Control unit without power-window lifter, with radio control and alarm function (with interior monitoring) and alarm system with independent power supply LHD |
6Q0959433A 04 6Q0959433H 2Q | 6Q1959 801 04/2Q 6Q1959 802 04/2Q | 0002 TFK 0001 | Control unit with 2 power-window lifters, without radio control and alarm function LHD |
6Q0959433C 06 6Q0959433E 2S | 6Q1959801 06/2S 6Q1959802 06/2S | 0002 TFK 0001 | Control unit with 2 power-window lifters, with radio control and without alarm function LHD |
6Q0959433C 08 6Q0959433E 2U | 6Q1959801 08/2U 6Q1959802 08/2U | 0002 TFK 0001 | Control unit with 2 power-window lifters, with radio control and alarm function (with interior monitoring) and alarm system with independent power supply LHD |
6Q0959433C OL 6Q0959433E OL | 6Q1959801 OL 6Q1959802 OL | 0002 TFK 0001 | Control unit with 2 power-window lifters, with radio control and alarm function (with interior monitoring) without alarm system with independent power supply LHD |
6Q0959433A 05 6Q0959433H 2R | 6Q1959801 05/2R 6Q1959802 05/2R 6Q1959811 05 6Q1959812 05 | 0002 TFK 0001 | Control unit with 4 power-window lifters, without radio control and alarm function LHD |
6Q0959433C 07 6Q0959433E 2T | 6Q1959801 07 6Q1959802 07/2T 6Q1959811 07/2T 6Q1959812 07 | 0002 TFK 0001 | Control unit with 4 power-window lifters, with radio control and without alarm function LHD |
6Q0959433C 09 6Q0959433E 2V | 6Q1959801 09/2V 6Q1959802 09/2V 6Q1959811 09/2V 6Q1959812 09/2V | 0002 TFK 0001 | Control unit with 4 power-window lifters, with radio control and alarm function (with interior monitoring) and alarm system with independent power supply LHD |
6Q0959433C OM 6Q0959433E OM | 6Q1959801 OM 6Q1959 02 OM 6Q1959811 OM 6Q1959812 OM | 0002 TFK 0001 | Control unit with 4 electrical window lifters with radio control and alarm function (with interior monitoring) without alarm system with independent power supply LHD |
6Q0959433A 0A 6Q0959433H 2E | - | 0002 | Control unit without power-window lifter, without radio control and without alarm function RHD |
6Q0959433C 0B 6Q0959433E 2X 6Q0959433F 2X | - | 0002 | Control unit without power-window lifter, with radio control and without alarm function RHD |
6Q0959433C 0C 6Q0959433E 2Y | - | 0002 | Control unit without power-window lifter, with radio control and alarm function (with interior monitoring) and alarm system with independent power supply RHD |
6Q0959433A 0D 6Q0959433H 2Z | 6Q1959801 0D/2Z 6Q1959802 0D/2Z | 0002 TFK 0001 | Control unit with 2 power-window lifters, without radio control and alarm function RHD |
6Q0959433C 0F 6Q0959433E 31 6Q0959433F 31 | 6Q1959801 0F/31 6Q0959802 0F/31 | 0002 TFK 0001 | Control unit with 2 power-window lifters with radio control and without alarm function RHD |
6Q0959433C 0H 6Q0959433H 33 | 6Q1959801 0H/33 6Q0959802 0H/33 | 0002 TFK 0001 | Control unit with 2 power-window lifters, with radio control and alarm function (with interior monitoring) and alarm system with independent power supply RHD |
6Q0959433A 0E 6Q0959433H 30 | 6Q1959801 0E30 6Q1959802 0E/30 6Q1959811 0E/30 6Q1959 812 0E/30 | 0002 TFK 0001 | Control unit with 4 power-window lifters, without radio control and alarm function RHD |
6Q0959433C 0G 6Q0959433E 32 6Q0959433F 32 | 6Q1959801 0G/32 6Q1959802 0G/32 6Q1959811 0G/32 6Q1959812 0G/32 | 0002 TFK 0001 | Control unit with 4 power-window lifters with radio control and without alarm function RHD |
6Q0959433C 0J 6Q0959433E 34 | 6Q1959801 0J/34 6Q1959802 0J/34 6Q1959811 0J/34 6Q1959812 0J/34 | 0002 TFK 0001 | Control unit with 4 power-window lifters, with radio control and alarm function (with interior monitoring) and alarm system with independent power supply RHD |
6Q0959433C 0N 6Q0959433G 3B | 6Q1959801 09/3B 6Q1959802 09/3B 6Q1959811 09/3B 6Q1959812 09/3B | 0002 TFK 0001 | Control unit with 2 power-window lifters, without radio control and alarm function LHD |
6Q0959433G 36 | 6Q1959801 36 6Q1959802 36 | 0002 TFK 0001 | Control unit with 2 power-window lifters, without radio control and alarm function RHD |
6Q0959433 F 37 | 0002 TFK 0001 | Control unit without power-window lifter, with 315 MHz radio control and alarm function (with interior monitoring) and alarm system with independent power supply RHD | |
6Q0959433F 38 | 6Q1959801 38 6Q1959802 38 | 0002 TFK 0001 | Control unit with 2 power-window lifters, with 315 MHz radio control and alarm function (with interior monitoring) and alarm system with independent power supply RHD |
6Q0959433F 39 | 6Q1959801 39 6Q1959802 39 6Q1959811 39 6Q1959812 39 | 0002 TFK 0001 | Control unit with 4 power-window lifters, with 315 MHz radio control and alarm function (with interior monitoring) and alarm system with independent power supply RHD |
|