skoda Workshop Repair Guides

Skoda Workshop Service and Repair Manuals

Fault table of LIN databus/control units for window control in the individual doors > < Coding control unit with LIN databus coding
Fault table of control unit for convenience system with LIN databus cable
Fault table of control unit for convenience system with LIN databus cable
  Note
t  Below is a list of all possible faults detected by the central control unit for convenience system -J393- and displayed on -V.A.G 1552 -, arranged according to their 5-digit fault code.
t  SAE code, may be displayed on the right next to the fault number (e.g. 4214), ignore.
t  If “Info in literature” appears in the display of the vehicle system tester, look for the text required in the fault table under the fault code.
t  After repair always interrogate the fault memory using vehicle system tester -V.A.G 1552- and erase the memory.
t  If parts are output as faulty: First check all cables and connectors to these components as well as the earth connections according to the Current Flow Diagram. Then check whether all plug connections are properly plugged into the relay plate. Replace the component only if this test does not reveal any fault. This applies in particular if faults are shown as “sporadic” (SP).
   
Display on V.A.G. 1552Possible cause of faultRectifying fault
65535
no fault detected
 If after repair “No fault detected” is displayed, the self-diagnosis is completed.
00849
S contact on ignition starter switch D -D-
undefined switch status
t  Terminal 15 O.K., S contact defective
–  Reading measured value block → Chapter
 
t  Cables or plug connections defective
–  Check wiring and plug connections according to the current flow diagram
00928
Locking unit for CL driver's side -F220-
Implausible signal
t  Locking unit defective
–  Reading measured value block → Chapter
–  Replace locking unit
 
t  Cables or plug connections defective
–  Check wiring and plug connections according to the current flow diagram
 
t  No supply voltage for CL on driver's door
–  Check supply voltage
 
t  Resistance in the mechanism of the locking unit and control elements
–  Check mechanism and ensure smooth operation
wrong equipment
t  other locking unit type fitted → Note
–  Replace locking unit
00929
Locking unit for CL front passenger's side -F221-
Implausible signal
t  Locking unit defective
–  Reading measured value block → Chapter
–  Replace locking unit
 
t  Cables or plug connections defective
–  Check wiring and plug connections according to the current flow diagram
 
t  No supply voltage for CL on passenger's door
–  Check supply voltage
 
t  Resistance in the mechanism of the locking unit and control elements
–  Check mechanism and ensure smooth operation
wrong equipment
t  other locking unit type fitted → Note
–  Replace locking unit
00930
Locking unit for RL CL -F222-
Implausible signal
t  Locking unit defective
–  Reading measured value block → Chapter
–  Replace locking unit
 
t  Cables or plug connections defective
–  Check wiring and plug connections according to the current flow diagram
 
t  No supply voltage for CL on rear left door
–  Check supply voltage
 
t  Resistance in the mechanism of the locking unit and control elements
–  Check mechanism and ensure smooth operation
wrong equipment
t  other locking unit type fitted → Note
–  Replace locking unit
00931
Locking unit for CL rr -F223-
Implausible signal
t  Locking unit defective
–  Reading measured value block → Chapter
–  Replace locking unit
 
t  Cables or plug connections defective
–  Check wiring and plug connections according to the current flow diagram
 
t  No supply voltage for CL on rear right door
–  Check supply voltage
 
t  Resistance in the mechanism of the locking unit and control elements
–  Check mechanism and ensure smooth operation
wrong equipment
t  other locking unit type fitted → Note
–  Replace locking unit
00948
Close sliding roof signal
Short circuit to positive
t  Cables or plug connections defective
t  Sliding roof switch defective
t  Sliding roof motor defective
–  Check wiring and plug connections according to the current flow diagram
–  Replace sliding roof switch
–  Replace sliding roof motor
00949
Motor for CL tailgate -V53-, LOCK
undefined switch status
t  Motor for CL tailgate defective
–  Replace motor for CL tailgate
 
t  Cables or plug connections defective
–  Check wiring and plug connections according to the current flow diagram
 
t  Lock control mechanism defective
–  Check lock control mechanism and ensure smooth operation
00950
Motor for CL tailgate -V53-, UNLOCK
undefined switch status
t  Motor for CL tailgate defective
–  Replace motor for CL tailgate
 
t  Cables or plug connections defective
–  Check wiring and plug connections according to the current flow diagram
 
t  Lock control mechanism defective
–  Check lock control mechanism and ensure smooth operation
00955
Key 1
Adaptation threshold (mul) exceeded
t  Key not adapted
–  Reading measured value block → Chapter
 
t  Key was operated over 200 times outside the reception range
–  Perform adaptation → Chapter
00956
Key 2
Adaptation threshold (mul) exceeded
t  Key not adapted
–  Reading measured value block → Chapter
 
t  Key was operated over 200 times outside the reception range
–  Perform adaptation → Chapter
00957
Key 3
Adaptation threshold (mul) exceeded
t  Key not adapted
–  Reading measured value block → Chapter
 
t  Key was operated over 200 times outside the reception range
–  Perform adaptation → Chapter
00958
Key 4
Adaptation threshold (mul) exceeded
t  Key not adapted
–  Reading measured value block → Chapter
 
t  Key was operated over 200 times outside the reception range
–  Perform adaptation → Chapter
01030
Lock the CL key switch on the driver's side
Short circuit to earth
t  Cables or plug connections defective
–  Reading measured value block → Chapter
 
t  Lock cylinder defective
–  Replace lock cylinder
 
t  Lock cylinder loose
–  Check lock cylinder installation
01031
Unlock the CL key switch on the driver's side
Short circuit to earth
t  Cables or plug connections defective
–  Reading measured value block → Chapter
 
t  Lock cylinder defective
–  Replace lock cylinder
 
t  Lock cylinder loose
–  Check lock cylinder installation
01032
Lock the CL key switch on the passenger's side
Short circuit to earth
t  Cables or plug connections defective
–  Reading measured value block → Chapter
 
t  Lock cylinder defective
–  Replace lock cylinder
 
t  Lock cylinder loose
–  Check lock cylinder installation
01033
Unlock the CL key switch on the passenger's side
Short circuit to earth
t  Cables or plug connections defective
–  Reading measured value block → Chapter
 
t  Lock cylinder defective
–  Replace lock cylinder
 
t  Lock cylinder loose
–  Check lock cylinder installation
01038
Central locking thermo fuse
 
t  Cables or plug connections defective
–  Reading measured value block → Chapter
 
t  Resistance in door lock
–  Check door lock
01044
Control unit wrongly coded
 
t  another control unit used
–  Replace control unit
 
t  Control unit wrongly coded
–  Check control unit coding
01134
Alarm horn -H12-
undefined switch status
t  Cables or plug connections defective
–  Check wiring and plug connections according to the current flow diagram
defective
t  Alarm horn defective
–  Replace alarm horn
No communication
t  Cables or plug connections defective
–  Check wiring and plug connections according to the current flow diagram
internal power supply
t  Alarm system with independent supply defective
–  Check alarm system with independent supply, if necessary replace
01135
Sensors for interior monitoring
Open circuit
t  Cables or plug connections defective
–  Check wiring and plug connections according to the current flow diagram
defective
t  Sensors for interior monitoring defective
–  Replace sensors for interior monitoring
 
t  Sensors for interior monitoring not fitted
–  Check the connection of sensors
01179
Key programming, wrong
 
t  The key adaptation was not carried out correctly
–  Adapt key again → Chapter
 
–  Reading measured value block → Chapter
01312
Databus drive
please read out fault memory
t  No communication between units
t  No speed signal or Gateway
–  Read out fault memory of vehicle voltage control unit → Rep. Gr.90
01322
Control unit for multi-function unit
No communication
t  No communication between units
–  Read out fault memory of electrical system control unit → Rep. Gr.90
please read out fault memory 
01330
Central control unit for convenience system -J393-
defective
t  Control unit -J393- defective
–  Replace control unit -J393-
t  If the communication cable between the units or control unit is O.K.:
–  Erasing fault memory
–  Perform a functional test
Voltage supply too high
t  Voltage supply N.O.K.
l  Voltage supply must be in the range 6.3...18 volts
–  Reading measured value block → Chapter
–  Check cables, plug connections and fuses in accordance with the current flow diagram
–  Checking voltage supply
Voltage supply too low
t  Battery discharged or defective
–  Replace battery or charge battery
 
t  Voltage regulator or AC generator defective
–  Check voltage regulator or AC generator → Rep. Gr.90
01336
Group convenience data bus
defective
t  Data bus cable defective
–  Replace cable harness
 
t  Cables or plug connections defective
–  Check wiring and plug connections according to the current flow diagram
 
t  CU defective
–  Replace the CU blocking the data bus for convenience functions
–  Disconnect all doors and re-connect in sequence. While doing so observe measured value block
 
t  No communication between units
–  Check vehicle voltage control unit
in single-filament operation
t  Data bus defective (data bus in emergency operation)
–  Reading measured value block → Chapter
–  Check wiring and plug connections according to the current flow diagram
01337
Inside door handle lighting
Short circuit to positive
t  Cables or plug connections defective
–  Check cables, plug connections and fuses in accordance with the current flow diagram
 
t  Inside door handle lights defective
–  Replace inside door handle lights
–  Reading measured value block → Chapter
01338
Signal: doors not closed
Short circuit to positive
t  Cables or plug connections defective
–  Check cables, plug connections and fuses in accordance with the current flow diagram
–  Reading measured value block → Chapter
 
t  Outlet CU for convenience system defective
–  Replace control unit for convenience system
01358
Switch for inside locking, driver's side -E150-
Implausible signal
t  Cables or plug connections defective
–  Check cables, plug connections and fuses in accordance with the current flow diagram
 
t  Switch -E150- defective
–  Replace switch
 
t  Switch -E150- loose
–  Check switch fastening
  
–  Reading measured value block → Chapter
01359
Switch for inside locking, passenger's side -E198-
Implausible signal
t  Cables or plug connections defective
–  Check cables, plug connections and fuses in accordance with the current flow diagram
 
t  Switch -E198- defective
–  Replace switch
 
t  Switch -E198- loose
–  Check switch fastening
  
–  Reading measured value block → Chapter
01362
Switch for tailgate: close -F124- → Note
Short circuit to earth
t  Cables or plug connections defective
–  Check wiring and plug connections according to the current flow diagram
 
t  Resistance in lock control mechanism or lock cylinder
–  Check lock control mechanism and ensure smooth operation
–  Replace lock cylinder
 
t  Switch for tailgate -F124- defective
–  Replace switch for tailgate -F124-
 
t  Switch for tailgate -F124- loose
–  Check switch fastening -F124-
  
–  Reading measured value block → Chapter
01389
Open switch for tailgate -F124- → Note
Implausible signal
t  Cables or plug connections defective
–  Check wiring and plug connections according to the current flow diagram
Short circuit to earth
t  Resistance in lock control mechanism or lock cylinder
–  Check lock control mechanism and ensure smooth operation
–  Replace lock cylinder
 
t  Switch for tailgate -F124- defective
–  Replace switch for tailgate -F124-
 
t  Switch for tailgate -F124- loose
–  Check switch fastening -F124-
  
–  Reading measured value block → Chapter

1)  A different Safe function is used in countries with special regulations.
2)  Not fitted on FABIA.
   

Fault table of LIN databus/control units for window control in the individual doors > < Coding control unit with LIN databus coding