| Check the sum of all misfirings since engine start in display field 3. |
Specified value: 0…10 (applies for max. 5 min after engine start) |
–
| Check the status of misfiring detection in display field 4. |
| Specified value: activated |
If the specified values are reached: |
–
| Select function 06 “End output” and confirm with Q. |
If the specified values are not reached: |
–
| Test ignition terminals and spark plugs → Chapter. |
|
|
Reading measured value block 14 -> | 800 rpm 34.0 % 0 activated |
|