| Read off intake manifold temperature in display field 4. |
| Specified value: approx. ambient temperature |
–
| Remove the intake manifold temperature sender -G72- with the intake manifold pressure sender -G71- (plug remains in position). |
–
| Note down the intake manifold temperature value in display field 4. |
–
| Spray the sender with a commercially available refrigerant spray and while doing so observe the temperature value. |
The temperature value must drop. |
If the specified values are not reached: |
–
| Select function 06 “End output” and confirm with Q. |
|
|
Reading measured value block 4 -> | 780 rpm 13.8 V 85.0 °C 28.5 °C |
|