Operation
Operation
The engine control unit is equipped with a fault memory. The fault memory is designed as a permanent memory.
If malfunctions occur in the monitored sensors or components, they are stored in the fault memory with indication of the fault type.
Faults that only occur temporarily (sporadically) are displayed with the suffix “/SP”. Possible causes of sporadic faults are e.g. a loose contact or a temporary line interruption. If a sporadic fault no longer occurs after 40 engine starts, it is erased from the fault memory.
The stored faults can be read out with the vehicle system tester -V.A.G 1552- using programme card 5.0 and higher version or fault reader -V.A.G 1551 - using programme card 8.0 and higher version or vehicle system tester - VAS 5051- → Chapter.
After the fault(s) has(have) been removed the fault memory must be erased → Chapter.
  Note
The following description only relates to the vehicle system tester -V.A.G 1552-.
   