skoda Workshop Repair Guides

Skoda Workshop Service and Repair Manuals

Self-diagnosis II > < Interrogating and erasing fault memory
Performing actuator diagnosis
Performing actuator diagnosis
With the actuator diagnosis the following parts are activated in the sequence indicated:
   
1.Fuel pump relay -J17-
2.Solenoid valve 1 for activated charcoal filter -N80-
3.Secondary air inlet valve -N112- → Note
4.Secondary air pump relay -J299- → Note

1)  Disregard display
  Note
t  The actuator diagnosis can only be carried out when the engine is not running and the ignition is switched on.
t  The final control diagnosis is aborted when the engine is started or when a moment of momentum is detected.
t  The actuators are tested acoustically or by touch.
t  If final control diagnosis is to be repeated wirthout starting the engine in-between, switch ignition off for about 20 seconds.
Test conditions
l  Fuses must be OK in compliance with the current flow diagram.
Special tools and workshop equipment required
t  Vehicle system tester -V.A.G 1552-
t  Diagnostic cable -V.A.G 1551/3, 3A, 3B oder 3C-
Procedure
–  Connect vehicle system tester -V.A.G 1552-. Switch ignition on and select address word 01 “Engine electronics”.
–  Enter function 03 “Final control diagnosis”.
   
The fuel pump relay (on the relay plate, relay position 15) must click until the next actuator is activated by pressing .
  Note
During activation of the fuel pump relay the fuel pump should also be heard to run at intervals.
If the relay does not click:
–  Testing fuel pump relay → Chapter.
–  Press .
 
Actuator diagnosis                    ->
Fuel pump relay-J17
The solenoid valve (left next to coolant reservoir) must continue clicking until the next actuator is actuated by pressing .
If the solenoid valve does not click:
–  Testing Activated charcoal filter system solenoid valve 1 -N80- → Chapter.
–  Press .
 
Actuator diagnosis                    ->
Sol.valve 1 for act. char.filter -N80
Readout on display:
–  Ignore display and press .
 
Actuator diagnosis                    ->
Secondary air inlet valve -N112
Readout on display:
–  Ignore display and press .
 
Actuator diagnosis                    ->
Secondary air pump relay -J299
Readout on display:
–  Select function 06 “End output” and switch ignition off.
  Note
The ignition must be switched off after final control diagnosis is ended. If you do not switch off the ignition before again starting the engine, the engine will not start as the injectors and the ignition transformer will not be operated.
 
Actuator diagnosis                    ->
END

Self-diagnosis II > < Interrogating and erasing fault memory