| Read off readout in display field 2. |
Specified value: min. 11,5 V |
–
| Select function 06 “End output” and switch ignition off. |
If the specified value is not reached: |
–
| Connect test box -V.A.G 1598/31- to connector of wiring loom → Chapter. The engine control unit is not connected here. |
Testing voltage of terminal 30 |
–
| Measure supply voltage between sockets 1 + 62 of the test box: |
Specified value: min. 11,5 V |
If the specified value is not reached: |
Testing voltage of terminal 15 |
–
| Use multimeter to measure voltage between sockets 1 + 121 at the test box. |
Specified value: min. 11.5 V |
If the specified value is not reached: |
–
| Test cable connections to relay plate according to current flow diagram: |
|
|
Reading measured value block 4 -> | 840 rpm 13.6V 95.0°C 62.0°C |
|