skoda Workshop Repair Guides

Skoda Workshop Service and Repair Manuals

Measured value block 001 > < Reading measured value block
List of display groups
   
List of display groups
Display groupDisplay fieldDenomination
0011Supply voltage for the air conditioning system control unit -J301-
2Voltage for fresh air blower -V2-
31. Stage for the fresh air blower
42. Stage for the fresh air blower
0021Compressor output
2Coolant pressure via high pressure sender -G65-
3Conditions for regulating the compressor output
4Evaporator vent temperature sender via -G263-
0031Vent temperature sender, footwell via -G192-
2Vent temperature sender, centre via -G191-
3Interior temperature via dash panel temperature sensor -G56-
4Ignore
0041Actual feedback value of the potentiometer in the re-circulating air flap control motor -G143-
2Nominal feedback value of the potentiometer in the re-circulating air flap control motor -G143-
3Established value of the potentiometer in the re-circulating air flap control motor -G143- during fresh-air operation according to the basic setting
4Established value of the potentiometer in the re-circulating air flap control motor -G143- in re-circulating air operation according to the basic setting
0051Actual feedback value of the potentiometer - temperature flap control motor -G92-
2Nominal feedback value of the potentiometer - temperature flap control motor -G92-
3Established value of the potentiometer - temperature flap control motor -G92- in flap position: warm according to the basic setting
4Established value of the potentiometer - temperature flap control motor -G92- in flap position: cold according to the basic setting
0061Engine speed
2Engine speed increase
3Driving speed
4Reversing light switch
0071Immobilization time
2Status terminal X
3Terminal 58d
4Heating element for air auxiliary heating -Z35-
0081External temperature via ambient temperature sensor -G17-
2Coolant temperature via coolant temperature sender -G62-
3Signal for coolant temperature “too high”
4Compressor output limitation

   

Measured value block 001 > < Reading measured value block