Extractor, filler and measurement connections with actant head valve |
Note t
| Carefully screw in the handwheel of the service coupling after connecting the A/C service station and only so far until the valve of the service connection is safely opened (observe the pressure gauge, do not over-press the valve). |
t
| The tightening torque of the valve -3- is 9±1 Nm. |
|
|
|