skoda Workshop Repair Guides

Skoda Workshop Service and Repair Manuals

Pressures and temperatures in the refrigerant circuit and its arrangement > < Extractor, filler and measurement connections with Schrader valve
Extractor, filler and measurement connections with actant head valve
Extractor, filler and measurement connections with actant head valve
  Note
t  Carefully screw in the handwheel of the service coupling after connecting the A/C service station and only so far until the valve of the service connection is safely opened (observe the pressure gauge, do not over-press the valve).
t  The tightening torque of the valve -3- is 9±1 Nm.
   
Low-pressure side
1 - Base with outside thread and groove for O-ring
2 - O-ring 7,6 mm; 1,8 mm
3 - Valve with inside thread M8 x 1 for cap
4 - Gasket
5 - Cap
  S87-0142
High-pressure side
1 - Base with inside thread
2 - O-ring 10,8 mm; 1,8 mm
3 - Valve with groove for O-ring and inside thread M8 x 1 for cap
4 - Gasket
5 - Cap
  S87-0141

Pressures and temperatures in the refrigerant circuit and its arrangement > < Extractor, filler and measurement connections with Schrader valve