| Disconnect plugs -1-, -2- and -3- from the engine pump aggregate -4-. |
1 - | Data BUS plug and terminal 15 |
2 - | Earth plug and terminal 30 |
3 - | Plug of power-steering sensor -G250- |
Note t
| Residual hydraulic oil remains in the engine pump aggregate. When removing the pressure line some of this residual amount will flow out. |
t
| When tying up the hydraulic line make sure the bending radius of 100 mm is reached. |
|
|
|