Hose connections with spring strap ring > < Hose connections (Superb II, Octavia II, Fabia II, Roomster)
Assembly of hose connections with push-fit couplings
Assembly of hose connections with push-fit couplings
  Caution
The gasket ring for the push-fit coupling can be damaged, if the securing clamp is in the lock position during the assembly. This could result in a leakage. Observe the assembly instruction.
  Note
All hose connections of the charge air system are secured with spring strap clamps or push-fit couplings. For the push-fit couplings pay attention to the following points:
Removing
   
–  Release the push-fit coupling by pulling the securing clamp -arrow-. Disconnect hose/pipe without auxiliary tool.
Install
–  Observe that the retaining lugs latch when installing -A-.
–  When replacing the gasket ring, place the gasket ring in the groove of the charge air hose. Make sure that the gasket ring if fully seated all round in the groove.
–  Oil the sealing surface and the gasket ring.
  N21-0184
–  Move the securing clamp in the position “unlocked”-1-.
–  Insert the charge air hose up to the stop into the coupling.
–  Move the securing clamp in the position “locked”-2- and then once again press on the charge air hose.
–  Check for correct seating and the correct locking in place of the push-fit coupling by pulling on the hose.
  N21-10133