| Loosen spring strap clamp -1- on the air guide hose and remove the hose from the air filter. |
–
| Disconnect bleeder hose -2- and the plug on the air mass meter -3-. |
–
| Remove the air deflector -4- from the air filter. |
–
| Unscrew the fixing screw -5- from the air filter. |
–
| Carefully remove air filter from the top. |
Note Pay attention to correct positioning of the stop buffer on the bottom part of the air filter (front and rear side). |
–
| Installation is carried out in the reverse order. |
–
| Tighten fixing screw -5- to 8 Nm. |
|
|
|