The new generation of fluid reservoirs -6- has a dessicator cartridge and is directly installed on the condenser -5-. |
Note t
| Replace the fluid reservoir (if possible only the dessicator) if the refrigerant circuit was opened for a longer period of time (beyond the normal repair time) and humidity penetrated or if it is required because a specific complaint was made → Chapter. |
t
| Only remove the screw plug (dessicator housing) shortly before the installation. |
t
| The dessicator bag, which is located in a unclosed fluid reservoir (housing), will be saturated with humidity and become unusable after a short period of time. |
t
| If necessary, observe the arrow for the direction of flow when installing. |
|
|
|