skoda Workshop Repair Guides

Skoda Workshop Service and Repair Manuals

Removing and fitting the heating and air conditioning system control > < Climatic - Air conditioner with manual control - Part 2
Summary of components for heating and air conditioning system control
Summary of components for heating and air conditioning system control
  Note
t  As of MY 2011, control elements of a different shape
t  As of CW 46.2010, temperature flap mechanically operated via flex shaft (potentiometer Pos. -10-).
   
1 - Control for heating and air conditioning system
q   with air conditioning system control unit -J301-
t  is connected to other control units via CAN bus
t  receives information about the heating and cooling output requirement and sends corresponding signals to the regulating valve for the compressor or the temperature flap positioning unit
t  is checked by self-diagnosis → Vehicle diagnostic, testing and information system VAS 5051
2 - Plug - air conditioning wiring loom
3 - Plug - vehicle wiring loom
4 - Flex shaft
q   for positioning unit for air distribution flaps
q   removing and installing → Chapter
5 - Switch for fresh air blower -E9-
q   4 speeds
q   The air conditioning system is only activated when the fresh-air blower is switched on
6 - Rotary switch for air distribution flaps
q   manual control of the flaps via the flex shaft, see Pos. 4
q   fresh-air operation is automatically activated (no misting up of windscreen) if „defrost“ is switched on during re-circulating air operation; return to re-circulating air operation by again pressing the re-circulating air button
7 - Dash panel temperature sensor -G56-
q   with temperature sensor blower -V42-
q   no longer fitted as of CW 46.2010
8 - Switch for air conditioning system -E30-
q   The air conditioning system is only activated when the fresh-air blower is switched on
9 - Switch for fresh air and re-circulating air flap -E159-
10 - Potentiometer for temperature selector -G267-
q   Control of interior temperature from 16 to 31 °C
q   turning the rotary switch to the left or right up to the stop deactivates the temperature control (temperature flap is fully open or fully closed)
q   if the ambient temperature is higher than the set interior temperature, the air conditioning system must be activated.

   

Removing and fitting the heating and air conditioning system control > < Climatic - Air conditioner with manual control - Part 2