Fabia Mk2
Structure of the refrigerant circuit |
Note
All air conditioning components marked * as well as all refrigerant hoses and refrigerant lines must be repaired or replaced in service centres, as the refrigerant must first be drained off at a service position. |
HP = High-pressure side |
LP = Low-pressure side |
1 - | Oil drain plug* |
2 - | Compressor* |
3 - | Pressure relief valve* |
4 - | Regulating valve for compressor of air conditioning system -N280- |
5 - | Extractor, filler and measurement valve* |
q | High-pressure side |
6 - | Screw cap |
7 - | Condenser* |
8 - | Fluid container with dessicator insert* |
9 - | Connection with valve* |
10 - | High-pressure sender -G65- |
11 - | Expansion valve* |
12 - | Evaporator* |
13 - | Screw cap |
14 - | Extractor and measurement valve* |
q | Low-pressure side |