Separating quick couplings for refrigerant lines |
Note Repairs must only be carried out in specialist service centres which have suitably trained personnel and are fitted out for working on the refrigerant circuit. |
Special tools and workshop equipment required |
t
| Release tool -VAS 6127/3- |
Note t
| Whenever the quick coupling is disconnected, replace the O-ring, locking insert and circlip. |
t
| These parts are available as repair kit (6Q0 298 260 - for high-pressure line; 6Q0 298 260A - for low-pressure line). |
t
| The following describes the separating of the quick coupling of the low-pressure line. The work sequence for separating the quick couplings of the high-pressure line is the same. |
|
|
|