| Screw the detent part -VAS 5161/6- with the interlocking fork -VAS 5161/5- into the guide plate. |
–
| Slide the knurled spacer ring -VAS 5161/23-1- onto the assembly cartridge -VAS 5161/8-. |
–
| Connect the adapter to the compressed air with a commercially available intermediate piece and apply constant pressure. |
l
| Minimum pressure: 0.6 MPa (6 bar) overpressure. |
–
| Hook the pressure fork -VAS 5161/2- onto the detent part and push the assembly cartridge downwards. |
–
| Turn simultaneously the knurled screw of the assembly cartridge to the right, until the tips click into the valve collets. |
–
| Rotate the knurled screw to the left and to the right, by doing so the valve collets are pressed apart and are installed in the assembly cartridge. |
–
| Release the pressure fork. |
–
| Remove the assembly cartridge with the knurled spacer ring. |
–
| Remove the valve spring with the valve spring retainer. |
|
|
|