skoda Workshop Repair Guides

Skoda Workshop Service and Repair Manuals

Replacing the battery on vehicles with "start-stop" system > < Fault recognition and fault display
Battery recharging or starting by external source on vehicles with start-stop system
Battery recharging or starting by external source on vehicles with start-stop system
When recharging or starting by external source, pay attention to the following points:
Do not disconnect the earth strap of the battery when recharging.
First of all connect to the positive terminals using the charge or jump leads; then connect to the body mass (do not connect to the negative terminal of the battery).
  Note
t  The direct charging (starting aid) of the battery at the negative terminal results in the bypass of the battery monitoring control unit -J367- (then the current flow is not monitored by this control unit).
t  The values regarding the battery state, which are stored in the data bus diagnostic interface -J 533- (Gateway), would then no longer correspond to the values of the charged battery.
t  This can lead to the failure of the start-stop system.
t  Testing and charging the battery „Electrical System - General notes“ → Electrical System - General notes; Rep. gr.27.
   