Check specifications for throttle valve control unit in display fields 3 and 4: |
Specification in display field 3: 8 |
Specification in display field 4: ADP runs ADP O.K. |
If the specified values are reached: |
The adaptation was successfully performed. |
–
| End adaptation only after 30 s by pressing the → key. |
Note t
| If the basic setting is aborted by the control unit, this may be due to the following reasons: |
t
| The throttle valve does not reach the mechanical idling limit due to dirt, e.g. carbon deposits or another mechanical fault. |
t
| the battery voltage is too low. |
t
| the throttle valve control unit or the wiring is defective, test → Chapter. |
t
| If the basic setting is aborted, the fault is still in the fault memory. When the ignition is switched on again the basic setting is automatically performed again. |
|
|
System in basic setting 60 -> | 14 % 85 % 8 ADP o.k. |
|