| Connect the second contact of the injector with remote control, adapter cable and auxiliary cable to pos. term. |
–
| Initiating final control diagnosis. The fuel pump must run. |
–
| Operate remote control for 30 seconds. |
–
| Perform the measurement on all injectors. |
–
| Once all four injectors have been driven, position the graduated measuring glasses on an even base. |
Specified value: 133...157 ml |
–
| If the measured value of one or more injectors is outside the tolerance value, disconnect the fuel pump (terminate final control diagnosis) and replace the defective injector. |
–
| If the measured values are outside tolerance for all injectors, check fuel pressure. |
Note When testing the injection rate also check the jet formation. The jet must be the same for all valves. |
Pay attention to the following points before fitting the injectors: |
l
| Replace O-rings on all opened connecting points (to replace the front O-ring do not remove the plastic valve head cap - draw the O-ring over the plastic cap). |
l
| Moisten O-rings with clean engine oil |
l
| Pay attention to correct positioning of the injectors |
l
| Check perfect fit of the retaining clips |
–
| Installation occurs in reverse order. |
|
|
|